Limit Switch Setting

 
 

OPEN LIMIT

Adjust screw A if shutter open clockwise. (See fig.2)
Adjust screw B if shutter open anticlockwise. (See fig.1)
1. Turn the screw clockwise to decrease open limit.
2. Turn the screw anticlockwise to increase open limit.

 

CLOSE LIMIT

Adjust screw A if shutter close in clockwise. (See fig.3)
Adjust screw B if shutter close in anticlockwise. (See fig.1)
1. Turn the screw clockwise to decrease close limit
2. Turn the screw anticlockwise to increase close limit